        Hi!Welcome to Taian Demei Electromechanical Equipment Co.,Ltd.!
        Taian Demei Electromechanical Equipment Co.,Ltd.

        Focusing on the field of temperature calibration experimental equipment production

        DY-LDY Cold Mirror Dew Point Apparatus

        DY-LD01型冷鏡式露點(diǎn)儀(投入式)-20℃~+95℃.jpg

        DY-LDY Cold Mirror Dew Point Apparatus

        ◇ Product Introduction ◇ Product Features◇ Technical Indicator

        [Product Introduction]

        The principle of DY-LDY cold mirror dew point meter is based on the physical definition of dew point, and it is an internationally recognized standard of humidity measurement.The cold mirror dew point meter has the characteristics of high precision, no drift, long life and good repeatability.

        The mirror of the cold mirror dew point meter has been gold-plated, and the photoelectric measuring chamber is made of materials with excellent corrosion resistance to ensure the accuracy of the measurement data and adapt to the harsh working conditions.

        Range of application

        As a standard instrument for humidity dew point detection, cold mirror dew point meter is widely used in metrology detection, scientific research, military aerospace, medicine, tobacco, industrial production and other fields.

        [Technical indicators]

        Technical index of dew point

        Technical index of dew point

        Measuring range: -20~+85℃@20℃

        Refrigeration temperature difference: 45℃@20℃

        Uncertainty: ±0.2℃

        Separation rate: 0.01℃

        Repeatability: ±0.05℃

        Technical temperature index

        Measuring range: -40~+90℃

        Measurement: PT100 Class B 1/3 DIN B four-wire system

        Uncertainty: ±0.1℃

        Separation rate: 0.01℃

        Repeatability: ±0.05℃

        Instrument Technical Indicators

        Operating environment of main machine: -25~+55℃, 0~95%RH

        Display unit: T ambient temperature, DP dew point temperature, RH relative humidity, SH wet air specific humidity, AH absolute humidity, etc.

        Output: Modbus RTU communication, USB communication

        Sensor cable: 1.5m

        Response time: Refrigeration speed ≤0.8℃/S + equalization time (usually 15s)

        Sampling flow rate: 0.1~ 1NL /min

        Power supply: 220ACV 50HZ

        Schematic diagram of cold mirror dew point meter


        Operation and Maintenance

        Before starting the machine, please connect the power supply, dew point probe and temperature probe cable. After starting the machine, the initialization time will be about 5 minutes. After initialization, the measuring state will start.After use, directly turn off the power to health.

        Press the up and down key to switch display parameters, short press Enter to switch display parameters above, long press Enter to Enter the DBC function, automatically clean the mirror.

        Routine maintenance and precautions are as follows:

        DBC (Automatic Cleaning Function) mode should be set to automatic mode (Manual mode should be set under normal conditions) in the case of more dust.

        If contaminants are found in the mirror, distilled water or alcohol can be used to clean the surface of the mirror and optical lens to ensure the measurement accuracy.

        Turn off the power supply before cleaning.Clean and air dry before starting the machine.

        Main interface introduction

        Top Left Status

        The number represents the current refrigeration power percentage. When it reaches 100, it indicates that the upper refrigeration capacity has been reached

        Cool: probe refrigeration,

        The probe is heating

        Blan: The dew point is in equilibrium

        DBC: Mirror cleaning in progress

        Below sidebar status

        Max: Record the upper limit measurement for this parameter

        MIN: Record the lower limit measurement value of this parameter

        Shows the units represented by abbreviations as follows

        T: Ambient temperature

        Dp: Dew point temperature

        Rh: Relative humidity

        SH: Wet air humidity unit g/kg g/kg

        AH: Absolute humidity unit g/m3 g/m3 m3

        IH: Wet air enthalpy J /g joules /g

        PW: Current water vapor pressure in air unit hPa


        DY-LDY Cold Mirror Dew Point Apparatus

        DY-LDY Cold Mirror Dew Point Apparatus

        • Online message

        • Your name
          You must fill in your title
        • TEL
          Must fill in mobile phone number
        • Email
          Required
        • Company
          Optional
        • Whatsapp/Skype
          Optional
        • Type of consultation
          Required, please select the type of consultation
        • Consultation content
          Required, what do you want to consult?
        • Verification code: Please fill in the calculation result.
        DY-LDY Cold Mirror Dew Point Apparatus 2020-12-6 This article was read 898 Times
        Previous:DY-HT3F-D Split portable high temperature short cavity blackbody furnaceNext:DY-HT3F-D Split portable high temperature short cavity blackbody furnace

        Technical

        Contact us

        Taian Demei Electromechanical Equipment Co.,LTD.

        Address:Building A8,No.98, South Nianhua Street,Shengzhuang Town,Taishan District,Tai'an City,Shandong Province,China

        Tel: +86-538-6518288

        Contact: Fred Xu   Email: fred@dmthermo.com

        Mobile/Wechat/Whatsapp: +86 15966019173



        Taian Demei Electromechanical Equipment Co.,LTD.             Lu ICP No. 14019246-4             Publicity

        激情综合站,66成人,欧美人在线一区二区三区,女人18毛片免费视频播放 龙川县| 逊克县| 买车| 慈利县| 岳阳县| 达拉特旗| 章丘市| 闽侯县| 英超| 集贤县| 桂东县| 天门市| 迁西县| 磐石市| 博兴县| 天门市| 福安市| 商城县| 万山特区| 夹江县| 酒泉市| 东乌珠穆沁旗| 雷波县| 南丹县| 满城县| 育儿| 会理县| 梅河口市| 遵义县| 安溪县| 黑水县| 七台河市| 区。| 上高县| 曲麻莱县| 绥棱县| 龙口市| 恩平市| 儋州市| 托克逊县| 塔河县| http://444 http://444 http://444 http://444 http://444 http://444